Retrotech DM-2A Manual de usuario Pagina 45

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 60
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 44
Retrotec Energy Innovations, Ltd.
37
DM-2A Mark II 2008-02-22
Appendix A
Configuring and Using the DM-
2A for Specific Standards
Different unit measurement conventions are often used and/or required in different
jurisdictions and vary according to the standards set out by local codes and authorities. You
can configure your DM-2A mark II gauge to adhere to virtually any code or standard in a
few moments using the procedures described previously in this user guide. See Accessing
Configuration Modes in Section 5 Using Advanced Configuration Modes.
The following section details the recommended configurations you will need to set your DM-
2A mark II gauge to in order to obtain measurements based on specific standards.
CGSB 149.10 Configuration
To configure your DM-2A mark II gauge to display measurements and adhere to the Canadian
General Standards Board (CGSB) 149.10, choose the following options:
CGSB 149.10 Configuration
Mode Setup Pressure Pa
Flow l/s @ 25Pa
EfLA Off -
EqLA cm
2
@ 10Pa
Air Changes /h @ 50Pa
Flow per Area Off
EqLA per Area cm
2
/m
2
@ 10Pa
Velocity Off
Velocity Flow Off
(Other Settings) n .65
Power Down Hour 2
Area m
2
Volume m
3
European No
Sig Figs 2.5
Reverse Mode No
DM-2A Mark II Dual-Channel Pressure Gauge User Manual
A: Specific Configurations
Vista de pagina 44
1 2 ... 40 41 42 43 44 45 46 47 48 49 50 ... 59 60

Comentarios a estos manuales

Sin comentarios